Abstract
Abstract. Magnetic fluid revolving sealing is widely used in modern industry. In the process of application, it is founded that the starting friction torque is very large, particularly at lower temperature. This problem has become a key factor restricting the application of magnetic fluid rotation sealing. In this paper, the mechanism of starting torque increase is analyzed, based on the change of microstructure and its viscosity. After analysis , such conclusion is obtained , which can be described: to a certain sealing structure, the type of magnetic fluid, size distribution of magnetic particles as well as the working condition concluding temperature, magnetic field gradient and the revolving velocity of shaft is the main influence factor of starting friction torque . It is very useful to reduce the starting friction torque.