Abstract
Tri-sectional regenerative air heater is used widely because of its compactness and better performance. Study on the matching analytical calculation method of heat transfer is rarely carried out because of the complicated heat transfer process. This paper developed a model to solve the heat transfer calculation of multi-sectional regenerative air heaters, which usually have several layers. Then we designed the computational procedure to carry out the model. One example of a tri-sectional regenerative air heater with hot layer and cold layer shows the effectiveness of the algorithm, and the results suggest that this approach is valid. The impact of leakage on performance of the regenerative air heater was discussed. There is a negative linear correlation between exhaust gas temperature and air leakage, and boiler efficiency has a nearly linear negative correlation with air leakage.
Publisher
Trans Tech Publications, Ltd.
Reference14 articles.
1. R.K. Shah, and D. P. Sekulić, Fundamentals of Heat Exchanger Design (John Wiley & Sons, Inc., Hoboken, NJ, USA. 2003).
2. N. Ghodsipour, and M. Sadrameli, Experimental and sensitivity analysis of a rotary air preheater for the flue gas heat recovery. Appl. Therm. Eng., 2003, 23 (5): 571-580.
3. D.F. Che, Boilers : theory, design and operation (Xi'an Jiaotong University Press, Xi'an , China. 2008).
4. R.K. Shah, Advances in science and technology of compact heat exchangers. Heat Transf. Eng., 2006, 27 (5): 3-22.
5. A.L. London, and R. A. Seban, A Generalization of the Methods of Heat Exchanger Analysis. Int. J. Heat Mass Transf., 1980, 23 (1): 5-16.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献