Affiliation:
1. Harbin Institute of Technology
Abstract
Based on analysis of the equivalent circuit mathematics model of helical Exploding Magnetic Generator of Frequency (EMGF), this paper discussed the influence in time and frequency domain on the load current by inductance variation which include number of turns, and expansion velocity.
Publisher
Trans Tech Publications, Ltd.
Reference7 articles.
1. L. L. Altgilbers, V. V. Onoochin: Analysis of the equivalent circuit of prishchepenko-type spiral MCGs, in 12th IEEE International Pulsed Power Conference (1999), pp.1260-1263.
2. P. Appelgren, G. Bjarnholt and N. Brenning: IEEE Transactions on Plasma Science. Vol. 36(5) (2008), p.2673~2683.
3. K. Niayesh, J. Jadidian, E. Hashemi and E. Agheb: IEEE Transactions on Plasma Science. Vol. 36(5) (2008), p.2700~2707.
4. H. Xie, J. Wang, D. Sun, R. fan, Y. Liu: Journal of Electromegetic Wave and Application. Vol. 24(2-3) (2010), p.401~411.
5. B. M. Novac, I. R. Smith: Brief history and classification of magnetic flux compression generators. Electromagnetic Phenomena, Vol. 3(11) (2003), pp.358-365.