Abstract
It is difficult to establish the precise mathematical model of the outlettemperature of hot-blast stove in the real manufacturing, for the control system ishunting system, with uncertainty, time variation, and coupling. So it will be moredifficult to guarantee the effort of control, based on the control algorithm of precisemathematical model. Aiming at these problems, a new predictive control strategywhich can quickly suppress disturbances has been provided by this paper. Thestrategy is based on the idea of control of dynamic matrix control, and combinesdynamic matrix control and the advantages of both time optimal control. It is proved bythe simulation result that this strategy acts a good effect on the outlet temperaturecontrol of hot-blast stove and will quickly suppress the interference.
Publisher
Trans Tech Publications, Ltd.
Reference6 articles.
1. Ashoori A, Moshiri B, Khaki-Sedigh A, Bakhtiari MR. Optimal control of nonlinear fed-batch fermentation process using model predictive approach. Journal of Process Control,2009, 19: 1162-1173.
2. Ding Jun, Xu Yongmao. Single neuron adaptive PID controller and its application. Control Engineering of china, 2004, 11: 27-30.
3. XiuZhilong, Shao Huihe. Control of temperature in biological ferment process. Control Engineering of china, 2005, 12: 30-33.
4. Zhao Sharu. Study on temperature fuzzy control in ferment process. Journal of Tianjin Polytechnic University, 2008, 27: 70-73.
5. Hisbullah, Hussain M A, Ramachandran K B. Design of a fuzzy logic controller for regulating substrate feed to fed-batch fermentation. Institution of chemical Engineers 2003, 81: 138-146.