Affiliation:
1. North China Electric Power University
Abstract
For comprehensive research on the dynamics of U-tube natural circulation evaporator in plant, the modular and lumped parameters method is used to establish the mathematical model of U-tube steam generator. Steam generator is divided into three parts in the model: primary water side, U-tube metal side and secondary water side. Secondary water side includes five modules. Then, the dynamic simulation experiment can be made on the basis of the simulation model. The experiment results consistent with the actual data and the adaptability and rationality of the model are verified.
Publisher
Trans Tech Publications, Ltd.
Reference6 articles.
1. Zhang Long-fei, Zhang Da-fa, U-tube Steam Generator Model and Dynamic Simulation, J. Boiler Technology, 2006, 37 (04): 9-11.
2. Juhani Hyvarinen, Heat Transfer Characteristics of Horizontal Steam Generators under Natural Circulation Conditions, J. Nuclear Engineering and Design 166, 1996: 191-223.
3. Jo J C, Jhung M J, Kim W S, et al , Dynamic Characteristics of Steam Generator U-tubes with Defect, J. Nuclear Engineering & Design, 2005, 235(7): 821-831.
4. Zhou Gang, Zhang Da-fa, Yang Shi-ben, Simulation and Analysis on Dynamics Characteristic for Nuclear Steam Generator Water Level Process, J. Journal of System Simulation, 2006, 18(12): 3383-3386.
5. Shahab K, Zaffar M K, Malik M A, et al, A Review of Heat Exchanger Tube Bundle Vibrations in Two-Phase Cross-Flow, J. Nuclear Engineering & Design, 2004, 230: 233-251.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献