Affiliation:
1. Tianjin University
2. China Tianchen Chemical Engineering Corporation
Abstract
In this preparation, FCCU main fractionator and corresponding absorption-stabilization system are systemically simulated on the basis of industrial data. Through analysis, a heat exchanging column is added to improve the flowsheet before rich gas cooler to make good use of heat of the compressed rich gas. To decrease LPG lost along with dry gas, a dry gas compression-expansion refrigeration circle is proposed to offer refrigeration capacity in place of the cooling water for the absorber pumparounds. Compared with the regular scheme, energy consumption and C3+ components in dry gas is reduced respectively by 17.18% and 7.16% and LPG yield is increased by 0.41% simultaneously.
Publisher
Trans Tech Publications, Ltd.
Reference8 articles.
1. J.B. Bao, J. Ma: Chemical Engineer, Vol. 20 (2006), p.47 (In Chinese).
2. E.X. Lu, H.J. Zhang and Z.K. Chen: Chemical Engineering, Vol. 26 (1998), p.29 (In Chinese).
3. E.X. Lu, H.J. Zhang and Z.A. Zhu: Computers and Chemical Engineering, Vol. 24 (2000), p.1317.
4. Q. Pan, E.X. Lu and J.J. Li: Computer Aided Chemical Engineering, Vol. 20 (2005), p.499.
5. Y. Qin, W.J. Zhou and X.G. Li: Chemical Industry and Engineering Process, Vol. 25 (2006), p.54 (In Chinese).
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献