Affiliation:
1. Tianjin Polytechnic University
2. Tianjin University
Abstract
The paper presents the measurement system of the air plane fuel mass consisting of cylinder shell resonating density meter and double cylinders capacitance level meter. The finite element analysis method of ANSYS10.0 is used to analyze the performance of cylinder shell resonator density meter and double cylinders capacitance fuel level sensor. On the base of simulation, the cylinder shell is 45mm in length, 9mm in radius, and 0.08mm in thickness, the material is 3J53; the double cylinders capacitance is 8mm in inside diameter, 23.6mm in outside diameter, and 550 mm in length. The experiments show the uncertainty of cylinder shell resonating density meter is only 0.12%, the uncertainty of double cylinders capacitance level meter is only 0.2%, and the uncertainty of the fuel mass measurement system is 0.4%.
Publisher
Trans Tech Publications, Ltd.
Reference7 articles.
1. Bobovnik G, Mole N, Kutin J, Stok B, Bajsic I, Coupled finite-volume/finite-element modelling of the straight-tube Coriolis flowmeter[J], Journal of fluids and structures 20 (6), Aug 2005: 785-800.
2. Clark C, Cheesewright R, Experimental determination of the dynamic response of Coriolis mass flow meters[J], flow measurement and instrument 17 (1) Mar 2006: 39-47.
3. Raszillier H, Durst F, Ingenieur-Archiv, Coriolis-effect in mass flow metering[J], 1991, 61(3): 192-214.
4. Timo Veijola, Thierry Corman, Perter Enoksson, et al, Dynamic Simulation Model for Vibraring Fluid Density Sensor[J], Sensors and Actuarors, 1999, 76: 213-224.
5. Liu Guang-yu, Design and application of several novel sensors, Beijing: National Defence Industry Press, (1988).