Abstract

In this paper, steady state sensible performance analysis on multi pass parallel cross flow exchanger was considered. The inputs to the heat exchanger were described through meaningful physically significant parameters such as number of transfer units, capacity rate ratio and dimensionless input temperature. The inputs to the heat exchager were varied systematically and a parametric study was conducted to determine the thermal performance at each individual pass of the heat exchanger. Heat exchanger’s thermal performance was described through the discharge temperatures that were expressed in a dimensionless form. The results from the study were presented in the form of performance tables. The performance tables employed meaningful and industry recognized dimensionless input parameters and the heat exchanger‘s performance was described through dimensionless discharge temperatures at every pass of the heat exchanger. The developed performance tables shall serve two critical aspects. First, it will help the heat exchanger designers to readily choose an optimum heat exchanger. An undersized heat exchanger shall not deliver the requirements and likewise an oversized heat exchanger shall add unnecessary weight and cost. This aspect was clearly observed in this study as indefinetly increasing the number of transfer units (or surface area) beyond a threshold value didn’t enhance the heat transfer. By employing the performance tables as a guide, the heat exchanger designers can quickly ascertain the performance of the heat exchanger without having to perform simulations and/or lengthy calculations. Second, during operational phase of the heat exchanger, the performance tables can be used to understand the performance variation of the heat exchanger with respect to mass flow rates and/or can help the engineers to choose appropriate mass flow rates for the required heat transfer. The highest heat exchanger performance was observed at the lowest capacity rate ratio and likewise the lowest heat exchanger performance was observed at the highest capacity rate ratio. In-addition, during the operational phase, the performance tables can help to detect an underperforming heat exchanger and can help the engineers to schedule maintenance activity on the heat exchanger equipment.

Publisher

Trans Tech Publications, Ltd.

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3