Affiliation:
1. HAEPC Electric Power Research Institute
Abstract
In this paper, we have studied the mechanical abrasion of the filter bags used in Electrostatic-fabric Integrated Collector (EFIC) and baghouse systems. Four factors have been listed: the effect of improper structure design and installation, the effect of quality of filter bag and poor filter cages. Common problems have been discussed, and the corresponding advices have been proposed.
Publisher
Trans Tech Publications, Ltd.
Reference8 articles.
1. GB/T 13223-2011. Emission standard of air pollutants for thermal power plants.
2. GB/T 4915-2004. Emission standard of air pollutants for cement industry.
3. S. Wang, M. Zhao, J. Xing, Y. Wu, Y. Zhou, Y. Lei, K. He, L. Fu, J. Hao: Environ. Sci. Tech. vol. 44 (2010), 2490.
4. C. A. Pope, M. J. Thun, M. M. Namboodiri, D. W. Dockery, J. S. Evans, F. E. Speizer, and C. W. Heath: Am. J. Respir. Crit. Care Med. vol. 151 (1995), 669.
5. D.M. Li, Y. Guo, D. Z. Chang, Y. Li, H. Xing: Adv. Mater. Res. vol. 610-613 (2013) 2617.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献