Abstract
In this paper, common mode (CM) conducted perturbations are predicted and compared with experiments in a full-bridge transformer-isolated buck converter system, thanks to a complex approach based on experimental measurements and on the modeling of the complete equivalent circuit. Its different part are considered and represented by a circuit of lumped parameters. Simulation and experiment of CM emission in the conducted frequency range (150 kHz-30 MHz) are compared. It is shown that the CM emission in the system can be calculated by the proposed model, and experiment has successfully confirmed this approach.
Publisher
Trans Tech Publications, Ltd.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Introduction;Electromagnetic Compatibility of Electric Vehicle;2021