Abstract
The seismic performance of the axial fan used in nuclear power plants (NPP) is investigated by using the commercial FEM software ANSYS. In the modal analysis, the first five orders of the natural frequencies of the axial fan is obtained, as well as the corresponding vibration modes. And in the spectrum analysis, the complete quadratic mode combination method is applied to determine the dynamic response of the axial fan under a random seismic excitation. The simulation results show that the seismic performance of the axial fan satisfies the requirement of the RCC-M 2007 design codes.
Publisher
Trans Tech Publications, Ltd.
Reference9 articles.
1. C. T. Whitman, The case for nuclear power. 00077135. Business Week, 4050, (2007).
2. N. James, T. G. Sitharam, G. Padmanabhan, C. S. Pillai. Seismic microzonation of a nuclear power plant site with detailed geotechnical, geophysical and site effect studies. Natural Hazards, Vol. 71(2014), p.419.
3. Y. M. Lu. Place the reactor of nuclear power plant underground. Chinese Engineering Science, vol. 15 (2013), 04, p.41.
4. J. Hirose, K. Suzuki, N. Yoshika. Seismic capacity tests of motor operated fans in ventilation systems. ASME 2011 Pressure Vessels and Piping Conference, Vol. 8 (2012), p.181.
5. X. F. Yang, Y. Zhang, B.T. Sun, et al. Seismic analysis on canned motor pump used in nuclear power generating station. World Earthquake Engineering, 03 (2007), p.47.