Abstract
Nowadays, there are various devices to detect the power quality of AC grid, where uncertainty of voltage deviation is an important parameter to investigate the power quality. National standards specify several sinusoidal waveforms to detect it, usually implemented into the detecting devices. But these waveforms are not enough and a novel method of detecting measurement uncertainty of voltage deviation is proposed in this paper. A series of detection waveforms are designed using this method. The simulation results verify that the method is available to measure uncertainty of voltage deviation more accurately. Moreover, it can be used to justify whether the basic measurement time interval of voltage deviation meets IEC standard requirements.
Publisher
Trans Tech Publications, Ltd.
Reference6 articles.
1. Sean Elphick, Vic Gosbell, R.A. Barr: The Australian Long Term Power Quality Monitoring Project (ICHQP 2008. 13th International Conference on).
2. P. Sorensen, N. A. Cutululis, T. Lund, A. D. Hansen, T. Sorensen, J. Hjerrild, M. H. Donovan, L. Christensen, and H. K. Nielsen: Power Quality Issues on Wind Power Installations in Denmark (IEEE Power Engineering Society General Meeting, Tampa, June, 2007).
3. GB/T 12325-2008, Power quality-Deviation of supply voltage [S]. 2008. In Chinese.
4. IEC 61000-4-30, Testing and measurement techniques-Power quality measurement methods [S]. (2008).
5. GB/T 19862-2005, General requirements for monitoring equipments of power quality [S]. 2005. In Chinese.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献