Affiliation:
1. Shanghai Jiao Tong University
2. Shanghai University of Electric Power
Abstract
Life cycle analysis combined with technical economic evaluation method in the paper to control the cost of denitration. A simple model for denitration cost is developed. The influence of different flue gas concentration of NOx to the cost of unit denitration is analysed by life cycle analysis, includes construction, operation and decommissioning, which based on 600 MW coal-fired units. Preliminary calculations reveal that comparing with directly using the denitration technology of selective catalytic reduction (SCR), after using Air staged Low NOx Combustion Technology reduced NOx below 400mg/m3, using SCR denitration further decreased the concentration of NOx in flue gas to 100mg/m3 can save more than 44% of the general denitration cost. This can improve effectively the environmental protection and economy of the coal-fired unit.
Publisher
Trans Tech Publications, Ltd.
Reference4 articles.
1. S. С. Wood, Select the Right NOx Control Technology, Chemical Engineering Progress, Vol. 33, (1994),P..
2. L. Bárzaga-Castellanos, R. Neufert, G. Kayser, and B. Markert, Life cycle assessment of the selective catalytic reduction process for power plants, The International Journal of Life Cycle Assessment, Vol. 4(1999), pp.329-339.
3. Odeh, N.A. and T.T. Cockerill, Life cycle analysis of UK coal fired power plants. Energy Conversion and Management, Vol. 49(2008), pp.212-220.
4. Udo de Haes, H.A. and R. Heijungs, Life-cycle assessment for energy analysis and management. Applied Energy, Vol. 84(2007), pp.817-827.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献