Affiliation:
1. Universiti Sains Malaysia
Abstract
The purpose of the present study was to evaluate the effect of filler loading on the fracture toughness of light-cured dental resin composites (DRCs). The monomer Bis-GMA and TEGDMA (75/25 wt/wt) were mixed with treated micro-sized aluminum oxide (Al2O3) particles ranging from 40-60 wt% as filler. The composite samples were cured with LED for 80s. The bulk density (g/cm3) and apparent porosity (%) of the samples were determined according to the ASTM standard. The fracture toughness (KIC) values of the composites were determined using a single edge notched specimen in the three-point bending test. There was a significant difference in KICof the composites with different loading of Al2O3particles (p< 0.05). The highest amount of filler (60 wt%) reduced the KICvalue to 1.5 MPa.m1/2. As a conclusion, the Al2O3particles used as filler loading does have an effect on the mechanical properties of DRCs.
Publisher
Trans Tech Publications, Ltd.
Reference22 articles.
1. Y. Jan, B. Lee, C. Lin, and W. Tseng: J. Formos. Med. Assoc. Vol. (2012), pp.1-7.
2. Q. Chen, Y. Zhao, W. Wu, T. Xu, and H. Fong: Dent. Mater. Vol. 28 (2012), pp.1071-1079.
3. K.H. Kim, J.L. Ong, and O. Okuno: J. prost. dent. Vol. 87 (2002), pp.642-649.
4. I. Sideridou, V. Tserki, and G. Papanastasiou: J. Biomat. Vol. 23 (2002), pp.1819-1829.
5. N. Opdam, B. Loomans, F. Roeters, and E. Bronkhorst: J. Dent. Vol. 32 (2004), pp.379-383.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献