Affiliation:
1. Harbin Engineering University
Abstract
Electricity and high-temperature heating steam are the products of marine diesel enginecogeneration system, and the heat-electricity cost allocation ratio impact cogeneration systemoptimization directly. This paper described several existing cost allocation methods, and applied thereduced exergy method to specific marine diesel engine cogeneration system, then, established thecost allocation model to derive the detailed process and results of calculating heat-electricity costallocation ratio, and draw an conclusion that the reduced exergy method is the most reasonablemethod of cost allocation.
Publisher
Trans Tech Publications, Ltd.
Reference8 articles.
1. Sari Siitonen, Henrik Holmberg: Estimating the value of energy saving in industry by different cost allocation methods [J]. International Journal of Energy Research. 2012(36): 324-334.
2. Xuemin Yue: Reduced Exergy Method for Heat-Electricity Cost Allocation in Combined Heat and Power Plants [J]. Entropy. 2003(5): 432-443.
3. Shouguang Yao: Thermal system analysis of the ship[M]. Science Press. P177-188.
4. Xiao Feng; Lilun Qian and Yinian Cai: Rationally Allocating Cogeneration Costs[J]. Journal of Engineering Thermophysics. 1997, 18(4): 409-412.
5. Xueting Han; Jie Zhang; Guitang Chen and Zhongjin Zhang: On the conception of reduced exergy and its application. Journal of Engineering for Thermal Energy & power. 1998, 13(3): 204-207.