Affiliation:
1. China Academy of Ordnance Science
2. Xi'an Jiaotong University
3. Dalian University of Technology
Abstract
By means of mechanical properties test and microstructure observation,the relationship between mechanical properties ,microstructure graph of core-shell Ni/TiO2group particles concentration of EMR and different electric field, magnetic field or electric-magnetic field have been researched. It is found that with increasing of particles concentration, the properties are increased. But there is a critical range value, too high or too low particles concentrations are harmful to properties and microstructure. The best particles concentration of Ni/TiO2particles is about 30%. In the same field with increasing concentration, particles chain of electrorheological fluid under certain electric field become more strong,brawnier and interweaved each other.
Publisher
Trans Tech Publications, Ltd.