Abstract
The new Electromagnetic Imaging Tool (EMIT) is introduced in this study. It is also described that the basic inspection theory, system structure and applications. The EMIT can determine whether metal loss or casing damage has occurred internally or externally. A 3D casing image can be supplied, including horizontal, vertical profile. The experimental results show that the EMIT has a “high-resolution” for MFL method in the casing well because of the steel brush structure. The minimal diameter of the inspection hole is 4 mm, and the thickness determination error of casing wall is 0.4 mm. A number of examples from oilfield are presented.
Publisher
Trans Tech Publications, Ltd.
Reference7 articles.
1. J.M. Edwards, S.G. Stroud, Mccullough Tool Co., New Electronic Casing Caliper Log Introduced For Corrosion Detection, Journal of Petroleum Technology, Issue August, (1966), p.933.
2. G. Frisch, B. Mandal, Advanced Ultrasonic Scanning Tool and Evaluation Methods Improve and Standardize Casing Inspection, SPE Annual Technical Conference and Exhibition, 30 September-3 October, (2001), New Orleans, Louisiana.
3. X.F. Zhong, Y.X. Wu, et al., Ultrasonic tomography and its applications in oilfield. J. Zhejiang Univ SCI, 6A(12) (2005), p.1420.
4. D.R. Fincher, A.C. Nestle, Fincher Engineering Co. A., Review of Corrosion Monitoring Techniques, SPE Symposium on Handling of Oilfield Water, 4-5 December, (1972), Los Angeles, California.
5. X.F. Zhong, Y.X. Wu, et al., The Multi-Pipe String Electromagnetic Detection Tool and Its Applications. ICEMI (2007), IEEE PRESS, p.423.