Affiliation:
1. Universiti Teknologi Malaysia
2. Universiti Pendidikan Sultan Idris
Abstract
Acoustic properties are the main criteria to evaluate the compatibility of tested materials as a medical phantom. We determined the acoustic properties of konjac glucomannan (KGM) gel to verify its compatibility as a medical phantom. The acoustic properties measurement employed ultrasonic insertion technique and utilized two identical transducers of 5 MHz center frequencies. One KGM gel block with 5.62 mm thickness was used as sample to determine its longitudinal speed, acoustic impedance and attenuation coefficient at three different water temperatures; (21.5 ± 0.1), (22.5 ± 0.1) and (23.5 ± 0.1) °C. Findings indicated that its longitudinal speed and acoustic impedance increased from (1495 ± 1) to (1499 ± 1) m s-1 and (1.555 ± 0.001) to (1.559 ± 0.001) × 106 kg m-2 s-1 as the water temperature increased from (21.5 ± 0.1) to (23.5 ± 0.1) °C. It also indicated that its attenuation coefficient varied around (0.1303 ± 0.0107) to (0.1373 ± 0.0103) dB cm-1 with increasing water temperature. KGM gel is compatible to be a medical phantom since its acoustic properties are comparable to the acoustic properties of human soft tissue.
Publisher
Trans Tech Publications, Ltd.
Subject
Condensed Matter Physics,General Materials Science,Atomic and Molecular Physics, and Optics
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献