Affiliation:
1. Nakhon Pathom Rajabhat University
2. Suan Sunandha Rajabhat University
Abstract
This article, for comparison, the non-proportionality of light yield and energy resolution of BGO, LYSO and CsI(Tl) scintillators couple to the R1306 PMT readouts were investigated. At 662 keV from 137Cs source, the good energy resolution of 7.13% for CsI(Tl) superior than LYSO and BGO scintillators. The energy resolution on gamma-ray energy was also evaluated to expose the scintillator intrinsic resolution parameters. For non-proportionality of light yield, the study showed a light yield non-proportionality 0.35% of LYSO, the value is better than 4.82 % for CsI(Tl) and 1.53 % of BGO scintillators.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science