Affiliation:
1. Petrochina Southwest Oil and Gas Field Company
Abstract
The application of distributed temperature sensors(DTS) to monitor producing zones ofhorizontal well through a real-time measurement of a temperature profile is becoming increasinglypopular. The information from DTS can potentially be transformed to obtain the permeability alongto the wellbore and well completion method and so on. The relationship between these parametersand the real-time temperature distribution along the wellbore is very important. Based onmass-,momentum-,and energy-balance equations, this paper established a model to predict thetemperature along the horizontal wellbore. The models presented in this paper account for heatconvective, fluid expansion, heat conduction, and viscous dissipative heating. Wellbore temperaturecurves are plotted by computer iterative calculation. In addition, this paper revealed the relationshipbetween wellbore temperature distribution and different characteristics, such as permeability alongto the wellbore and well completion method. The analysis results show that permeability differenceand different well completion methods may lead to different downhole temperature distribution atthe same time step, different production rate, different wellbore temperature as well as the change offriction factor in the wellbore. From the temperature distribution and temperature derivative curvesin different cases, we could easily derive the permeability distribution along wellbore and thelocation of the perforated intervals and the fractures.
Publisher
Trans Tech Publications, Ltd.
Reference24 articles.
1. Hill AD. Temperature logging in Production logging–theoretical and interpretive elements,, SPE monograph series, Volume 14, Henry Doherty memorial fund of AIME society of petroleum engineers, Richardson, TX USA, (1990).
2. G. Brown, D. Storer, K. McAllister, M. Al-Asimi, K. Raghavan, Monitoring Horizontal Producers and Injectors During Cleanup and Production Using Fiber-Optic-Distributed Temperature Measurements, Soc. Pet. Engineers, paper SPE-84379-MS (2003).
3. M. Tolan, M. Boyle, G. Williams, The Use of Fiber-Optic Distributed Temperature Sensing and Remote Hydraulically Operated Interval Control Valves for the Management of Water Production in the Douglas Field, Soc. Pet. Engineers, paper SPE-71676-MS (2001).
4. H. Foucault, D. Poilleux, A. Djurisic, M. Slikas, J. Strand, R. Silva, A Successful Experience for Fiber Optic and Water Shut Off on Horizontal Wells with Slotted Liner Completion in an Extra Heavy Oil Field, Soc. Pet. Engineers, paper SPE-89405-MS (2004).
5. V. I. Fryer, D. ShuXing, Y. Otsubo, G. A. Brown, P. Guilfoyle, Monitoring of Real-Time Temperature Profiles Across Multizone Reservoirs during Production and Shut in Periods Using Permanent Fiber-Optic Distributed Temperature Systems, Soc. Pet. Engineers, SPE-92962-MS (2005).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献