Abstract
For flat plate of Q-235 Carbon Steel whose thickness is 4, 5 and 6mm, with the small hole that diameter is 3, 5 and 7 mm in the center and the load of 9, 18 and 27 KN at the both ends, the magnetic signal on the surface of the plate under the state of static tension conditions was detected by using CMT5305 and TSC-1M-4 test instruments. It is found that the magnetic signal on the surface of the sample is interrelated with stress concentration around the hole and diameter of the hole, while independent to thickness and load of the plate.
Publisher
Trans Tech Publications, Ltd.
Reference9 articles.
1. J.L. Ren, J.M. Lin: Electromagnetism nondestructive inspection(science and technology press. China . 2008).
2. O. Heczko, A. Sozinov, K. Ullakko, IEEE Trans. Magn. 36 (2000) pp.32-66.
3. Barnes, R. and Atherton, D. L. Effect of bending stresses on magnetic flux leakage patterns, NDT & E Ztitern 261 (1993) pp.3-6.
4. Barnes, R: Comparison of the effects of surface and uniform stresses on magnetic flux leakage signals (MSc Thesis, Queen's University , Kingston, 1993).
5. Atherton, D. L : Magnetic inspection is key to ensuring safe pipelines , (Oil Gus8732 (1989) pp.52-61).