Affiliation:
1. North China Institute of Water Conservancy and Hydroelectric Power
2. North China University of Water Source and Electric Power
Abstract
To meet the requirement of machine-made sand application in concrete structures, experimental studies were carried out on the bond of plain steel bar with Machine-made Sand Concrete (MSC) by the central pull-out test method. Three specimens were cast as one group, 14 groups were tested considering the influence of concrete strength, bond length and stone powder content in machine-made sand. Based on the experimental research, the characteristic values of bond-slip curve such as the initial-slip and ultimate bond stresses with corresponding slips are statistically analyzed, the bond-slip constitutive relations between plain steel bar and MSC were obtained.
Publisher
Trans Tech Publications, Ltd.
Reference10 articles.
1. Chinese Standard GB/T14684-2001: Sand for Building. China Building Industry Press, Beijing, (2001).
2. S. Zhao, M. Xia and C. Liu: Journal of Railway Science and Engineering, 2 (2006) 15-20.
3. S. Zhao, C. Liu, J. Ren and C. Li: Central-south Highway Engineering, 2 (2006) 37-41.
4. X. Zhang, X. Ding, S. Zhao and Z. Ge: Applied Mechanics and Materials. Vols. 71-78 (2011) 4361-4364.
5. F. Li and Q. Zhu: Advanced Materials Research, Vols. 152-153 (2011) 1479-1482.
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献