Abstract
This paper investigated the impact of area effect in the batch mode micro-EDM on shape accuracy and surface morphology of the machined microstructures, as well as electrode wear, using both the positive-type and the negative-type electrode arrays fabricated by the UV-LIGA process. Experimental results showed that ,with the increase of electrode-pair scale from Φ1mm, Φ2mm, Φ4mm to Φ8mm, the shape accuracy of the machined stainless steel microstructures increased, but the eroded microcavities of the machined area reduced in both the positive-type and the negative-type micro-EDM using the same electrical pulse parameters. It was also found that, with the same pulse energy and electrode-pair area, the electrode wear reduced as the electrode-couple area increased, and the wear ratio in the positive-type micro-EDM was larger than that in the negative-type micro-EDM.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Reference4 articles.
1. H. Guckel, K.J. Skrobis, T.R. Christenson and J. Klein: Proc. SPIE's 1994 Symposium on Microlithography, 1994, p.39.
2. K. Takahata, N. Shibaike and H. Guckei: Proc IEEE Micro Electro Mech Syst MEMS, 1999, p.238.
3. K. Takahata and Y.B. Gianchandani: J Microelectromech Syst, Vol. 11 (2002), p.102.
4. G. Tosello, G. Bissacco, P.T. Tang, H.N. Hansen and P.C. Nielsen: Microsyst Technol, Vol. 14 (2008), p.1757.