Abstract
Real-time monitoring of oil contamination in hydraulic system is one of the most effective measures of prevention and early diagnosis for system failures. A compact on-line particle counter sensor based on light-blockage principle for monitoring hydraulic oil is presented in the article. A novel method is used in this sensor, which can calculate the particle number concentration without a metering pump. The experimental results show that the particle counter sensor can measure the concentration as well as the approximate size of the hydraulic oil particles with a high precision.
Publisher
Trans Tech Publications, Ltd.
Reference4 articles.
1. Raadnui S., and Kleesuwan S. Low cost condition monitoring sensor for used oil analysis, Wear, 2005, 259: 1502-1506.
2. Apinun Youthapolnavee, Weerapong Chewpraditkul, Ake Chaisawadi. A construction of particle counter by using laser light scattering. 6th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, Chonburi, Thailand , 2009: 421-424.
3. Peng Z., and Kessissoglou N., An integrated approach to fault diagnosis of machinery using wear debris and vibration analysis, Wear, 2003, 255: 1221-1232.
4. Campbell P. On-line monitoring of ferromagnetic debris concentration, Proc. Int. Condition Monitoring Conf., 1991: 325-335.
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献