Affiliation:
1. Agricultural University of Hebei
Abstract
In collapse-resistant design of a structure under accidental local action, it is important to understand the failure mechanism and alternative load paths. In this paper, a pseudo-static experimental method is proposed. Based on which, the collapse of frame structure was simulated with testing a 1/3 scale; 4-bay and 3-story plane reinforced concrete frame. In the experience, the middle column of the bottom floor was replaced by mechanical jacks to simulate its failure, and the simulated superstructure’s gravity load acted on the column of the top floor by adopting a servo-hydraulic actuator with force –controlled mode.
Publisher
Trans Tech Publications, Ltd.
Reference6 articles.
1. ACI Committee 544. Measurement of properties of fiber reinforced concrete [J]. ACI Materials Journal 1988, 85 (6): 583-593.
2. ASTM C1018 Standard test method for flexural toughness and first crack strength of fiber reinforced concrete [S]. ASTM Standards for Concrete and Mineral Aggregates, V. 04. 02, Standard Designation C1018, (1989).
3. JCI-SF4 Method of test for flexural strength and flexural toughness of fiber reinforced concrete (Standard SF4) [S]. JCI Standards for Test Methods of Fiber Reinforced Concrete, Japan Concrete Institute, 1983: 45-51.
4. Abolhassan Astaneh-As, l Erik A Madsen, Charles Noble, eta. l Use of catenary cables to prevent progressive collapse of buildings [R/OL]. 2002 [2006-09-20]. http: /www. ce. berkeley. edu /~astaneh /1-Research /blast.