Affiliation:
1. Loyola University of Chicago
Abstract
The paper introduces an experimental process on measurement of ultra low sulfur in IN718 by using infrared carbon sulfur analyzer. The experimental data shows that, infrared absorption method can be used to analyze and measure the ultra low sulfur in IN718, and the precision and accuracy of this method meets the requirement of ASTM E l019-2000. It can be concluded that it is a feasible method in practice.
Publisher
Trans Tech Publications, Ltd.
Reference9 articles.
1. Qi Huan, University of Michigan-Shanghai Jiao Tong University Joint Institute, Materials Engineering 2012. 8, 92-100.
2. Dong J X, Xie X S, Thompson R G, The influence of sulfur on stress-rupture fracture in INCONEL 718 superalloys Science. 2000 September; vol. 31A, no. 9: 2135-2144.
3. Masatake Yamaguchi, Motoyuki, Hideo Kaburaki, Grain boundary decohesion by impurity segregation in a nickel-sulfur system, Science 307, 393(2005).
4. ISO 15350-2000 Steel and iron - Determination of total carbon and sulfur content - Infrared absorption method after combustion in an induction furnace (routine method).
5. ASTM E1019-11 Standard Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys by Various Combustion and Fusion Techniques.