Abstract
A new fluorescence immunoassay with high sensitivity, time-saving, good precision and reliablility was proposed for the determination of estradiol (E2) in human urine. The complex of FITC-labeled anti-E2antibody was produced and regarded as a probe in this system. Ninety-six microplate was coated with ovalbumin conjugated E2antigen as solid phase for the immunoassay. The method parameters affecting the determination, such as the concentration of immunoreagents, pH, and other relevant variable conditions upon the immunoassay were studied and optimized systematically. Under the optimal experimental conditions, it was found that the proposed method exhibited high performance with the detection limit of 9.2 pg/mL, and the linear range of determination of 0.01-1000 ng/mL. The recoveries were 93.58-105.82% with the relative standard deviations (RSD) 5.52-7.09%. The proposed method has been used for the determination of E2in human urine with satisfactory results, and may be expected to find wide application in other environmental samples.
Publisher
Trans Tech Publications, Ltd.
Reference8 articles.
1. V. Pacáková, L. Loukotokvá, Z. Bosáková and K. Štulík: J. Sep. Sci., Vol. 32 (2009), p.867.
2. M. Farre, M. Kuster, R. Brix and F. Rubio: J. Chromatogr., A, Vol. 1160 (2007), p.166.
3. F. Z. Stanczyk, I. Miyakawa and U. Goebelsmann: Am. J. Obstet. Gynecol., Vol. 137 (1980), p.443.
4. D.G. Cooke, J. E. Binnie and L. F. Blackwell: Steroids, Vol. 72 (2007), p.580.
5. D. Scalas, S. Squadrone, M. Gili, D. Marchis and M. Prearo: J. AOAC Int., Vol. 90 (2007), p.1427.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献