Fatigue Characteristics and Numerical Modeling Socket for Patient with above Knee Prosthesis

Author:

Abbas Saif M.1

Affiliation:

1. Al-Nahrain University

Abstract

In this research, two groups of composite materials were used for manufacturing Above –Knee (AK) prosthetic socket. These sockets were fabricated from resin lamination (80:20) siegalharz as matrix materials, N-glass and carbon as reinforced materials using vacuum pressure. The mechanical properties for materials that used in above knee socket were tested by tensile, bending and fatigue tests. The results showed the mechanical properties of (N-glass - carbon fiber-N-glass) with matrix of lamination (80:20) resin were: Ϭy= 112Mpa, Ϭult=132MPa, Ϭb max=57Mpa, E=1.74GPa and The elongation at Beak was 3.5mm. In addition, the test result of (N-glass - carbon fiber-N-glass) with matrix of siegalharz resin were Ϭy= 123Mpa, Ϭult=151MPa, Ϭb max=174Mpa, E=2.64GPa and the elongation at Beak was3.3mm. Interface pressure was measured for above knee prosthetic socket and the patient age (30years) , height (165 cm) and weight (83 kg). High pressure values of (190Kpa) and (164Kpa) were recorded for the anterior and lateral sections respectively. This is because of the anterior and lateral muscles action which tend to be more active during the movement of the patient. The numerical results showed that the safety factor for (N-glass - carbon fiber-N-glass) with matrix lamination of (80:20) resin was found to be 0.595in addition the safety factor for (N-glass - carbon fiber-Nglass) with matrix of siegalharz resin was numerically calculated to be 1.084 which is safe in design.

Publisher

Trans Tech Publications, Ltd.

Subject

Condensed Matter Physics,General Materials Science,Radiation

Reference16 articles.

1. Statistics in the hospital Ibn al-Quff center of Baghdad for prosthesis and orthosis, (2015).

2. Lippincott Williams &Wilkins, Prosthetics and Orthotics: Lower Limb and Spinal, chapter one. 2002:485.

3. Alan J Thurston, Paré and prosthetics: the early history of artificial limbs, ANZ journal of surgery, 77(12):1114–1119, (2007).

4. R, Pritham C, Wilson AB Jr, A short history of the quadrilateral above-knee socket, in Donovan: Report of ISPO Workshops, International Workshop on Above-Knee Fitting and Alignment. Copenhagen, International Society for Prosthetics and Orthotics, 1989, pp.4-12.

5. John Angelico, Prosthetic Primer: Transfemoral Prosthetics, Above Knee, in Motion journal, Volume 9 · Issue 3 · May/June (1999).

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3