Abstract
In the field of building construction, mass consumption of wood materials contributes to reforestation and becomes the environmental burden reduction. However, an application to conventional timber structures only such as house has a quantitative limit. A newly developed timber structure that is able to make a large-scale building is expected. A composite steel-timber structure will be one of the effective methods to expand the structural variations. In this paper, the bending test of composite steel-timber beam classified typical joint methods is conducted to grasp basic structural performance.
Publisher
Trans Tech Publications, Ltd.
Reference9 articles.
1. Architectural Institute of Japan: Proposal 2050 Vision, Building-related Measures to Counteract Global Warming Towards Carbon-Neutralization (2009).
2. Ministry of Agriculture, Forestry and Fisheries: Annual Report on Forest and Forestry in Japan (2011).
3. Mamoru Iwata, Masanori Fujita: A Damage-Controlled Structure Using Buckling-Restrained Knee Braces, Structural Engineering International, International Association for Bridge and Structural Engineering, SEI Volume 21, No. 4, pp.462-470 (2011).
4. Architectural Institute of Japan: Design Standard for Steel Structures -Based on Allowable Stress Concept- (2008).
5. Architectural Institute of Japan: Fundamental Theory of Timber Engineering (2012).
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献