Abstract
The harmonic current detection is an essential part for an active power filter (APF). A random harmonic current detection method for single-phase active power filter without the phase locked loop (PLL) is proposed. The detection errors caused by low pass filters are analyzed, and an improved method has been proposed which can increase the detection accuracy and response speed. This method can detect the single order harmonic current and decompose it. Theoretical analysis and simulation results show the validity of the proposed method.
Publisher
Trans Tech Publications, Ltd.
Reference17 articles.
1. El-Havrluk M, Darwish M K and Mehta P, Active power filters a review, Electric Power Application, vol. 147, no. 5, pp.403-413, (2000).
2. Gurguiatu G, Balanuta C, Rosu E, etal, Advanced Active Power Filter to improve power quality, IEEE International Aegean Conference on Electrical Machines and Power Electronics and 2011 Electromotion Joint Conference (ACEMP), Turkey, 2011, pp.484-489.
3. Li Zhanying, Ren Zhen and Yang Zeming, Survey on Active Power Filter Devices and Their Application Study, Power System Technology, vol. 28, no. 22, pp.66-70, (2004).
4. Kanjiya P, Khadkikar V and Zeineldin H H, Achieving maximum possible power factor with single-phase shunt active power filter under distorted supply condition, 2012 IEEE Fifth Power India Conference, India, 2012, pp.1-6.
5. Chaoui A, Gaubert J P, Krim F, etal, On the design of shunt active filter for improving power quality, IEEE International Symposium on Industrial Electronics (ISIE), 2008, pp.31-37.