Abstract
Permanent magnet synchronous motor mathematical models of synchronous rotating coordinate system are decoupled by rotor field orientation. Then, the speed regulator, current regulator and space vector control system are designed. The current inner ring and speed outer ring ensure the accurate tracking of current and the accurate control of speed. To reduce the control algorithm computation, SVPWM control strategy based on the 60o coordinate system is used on the permanent magnet synchronous motor control system. Simulation results show that the space vector control system has good dynamic characteristics and the control scheme is feasible.
Publisher
Trans Tech Publications, Ltd.
Reference6 articles.
1. Boshi Chen, in: Electric drive automatic control system, Beijing (2007), Machine press. In Chinese.
2. Tomonobu Senjyu,Yohei Noguchi: Position sensorless control for interior permanent magnet synchronous motors using H∞ flux observe. Electrical Machines, 2010 XIX International Conference, pp.1-6.
3. Wu R, Slemon G R: A permanent magnet motor drive without ashaft sensor. IEEE Industry Applications Society Annual Meeting, 1990, pp.553-558.
4. Reza Shahnazi, Hasan Modir Shanechi, Naser Pariz: A Novel Adaptive Fuzzy PI Sliding Mode Control. IEEE Transaction on Energy Conversion, 2008, pp.138-147.
5. Yonghong Du, Zhefeng Li, Zhigang Liu: Indirect Field Orientation Double Close Loop System of Induction Motor. Transactions of China Electrotechnical Society, Vol. 24(2009), pp.24-28. In Chinese.