Abstract
This paper presents a method for determining the rotor temperature of an electric motor by observing the dq-axis flux linkage. A reference dq-axis flux linkage is obtained at a defined rotor temperature. The difference between calculated and reference flux in the d-axis is supposed to be caused by temperature, therefore the temperature can be back-calculated according to the permanent magnet temperature characteristic. The proposed method was confirmed to be correct and effective by the test results.
Publisher
Trans Tech Publications, Ltd.
Reference9 articles.
1. K. Yamamoto, The development trend of a next-generation car and the its propulsion motor, Proc. ICEMS, pp.25-31, (2010).
2. H. Ohtsuka and F. Anraku, Development of inverter for 2006 model year civic hybrid, Proc. 4th Power Convers. Conf., pp.1596-1600, (2007).
3. M. Kamiya, Development of Traction Drive Motors for the Toyota Hybrid System, 2005 International Power Electronics Conference, pp.1474-1481, (2005).
4. G. Gallegos-Lopez, F.S. Gunawan and J. E. Walters, Optimum torque control of permanent magnet AC machines in the field-weakened region, Conference Record of the IEEE Industry Applications Conference, pp.254-260, (2004).
5. M. M. Bech, T. S. Frederiksen and P. Sandholdt, Accurate torque control of saturated interior permanent magnet synchronous motors in the field-weakening region, Industry Applications Conference, 2005. Fourtieth IAS Annual Meeting. Conference Record of the 2005, pp.2526-2532, (2005).