Development of Ultrasonic Based Air Bubble Detection and Safety System for Hemodialysis Machine to Prevent Embolism

Author:

Busono Pratondo1

Affiliation:

1. BPPT

Abstract

Hemodialysis is one of the treatment methods for the patients with end stage renal disease. It is conducted through the use of artificial kidney or dialyzer, located outside of the human body. During the hemodialysis therapy, small air bubbles may infiltrate through the blood tubing and coalesce to perform the larger bubble which can be harmfull for the patient if entering the patient’s blood circulatory system. The objective of this work is to develop an ultrasonic based air bubble detection system as well as the safety system, mainly the electronic system, for hemodialysis machine application. The safety systems consits an electronic for activating visual and sound alarms, and tube clamp. It is used for preventing the embolism during the hemodialysis therapy. The research method covers the conceptual design, detail design, prototyping and performance testing for both hardware and software. The hardware system consists of air detector module, analog circuitry which consists of transmitter and receiver, digital circuitry with DSP based SOM (system on module) and I/O interface. The software system has two main functions. It is for controlling the hardware and processing the signals digitally. The integration between the hardware and the software making the system be able to detect the presence of air bubble. In addition, the software had possess the capability for triggering a tube clamp as well as activating visual and audio alarms. The tubing clamp was used to stop the fluid flow in the blood tubing and prevent an air bubble from entering the patient circulatory system. The validation test was conducted to verify the functionality of the system. For testing purposes, an experimental flow loop was constructed. This loop consits of peristaltic pump, bubble injector, tube clamp, air flow meter, liquid flow meter, and bubble detector. Several test runs by using simulated blood (Dextran 70 solution) were performed. To test the performance of bubble detection system, comparison between measurement of PWM signals conducted using the DSP and oscilloscope was presented in this work. It shows that error procentage between two types of measurement is less than 5%.

Publisher

Trans Tech Publications, Ltd.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3