Abstract
The objective of this work is to do theoretically investigation about the solar fraction changing laws affected by some factors, so that we can do optimization for solar system designing, specially for household solar water heating system. The calculation of solar fraction was established on a more effective day-to-day simulation model rather than traditional method. It is found that the collector area and the water storage tank volume are the main influence factors. Economic analysis by means of lifecycle cost savings evaluation was carried out based on the calculated model.
Publisher
Trans Tech Publications, Ltd.
Reference11 articles.
1. Beckman W. A, Klein S. A and Duffie J.A. Solar heating design by the f-chart method, New York: John Wiley & Sons, (1977).
2. Klein S.A., Calculation of flat-plate collector utilizability, Solar Energy, vol. 21, pp.393-402, (1978).
3. Klein S. A, Beckman W.A., A General design method for closed-loop solar energy systems, Solar Energy, vol. 22, pp.269-282, (1979).
4. Huanxia Chen, The calculation about solar fration, Acta Energiae Solaris Sinica, vol. 2, pp.59-68, (1981).
5. Manuel Collares Pereira and Ari Rabl, Simple procedure for predicting long term average performance of nonconcentrating and of concentrating solar collectors, Solar Energy, vol. 23, pp.235-253, (1979).