Affiliation:
1. Harbin Engineering University
Abstract
To produce a better uniform magnetic field along the direction of light propagation in studying magnetometer, a pair of rectangular coils are used instead of traditional Helmholtz coils. In this work, the magnetic homogeneity in the center of the rectangular coils is calculated and discussed theoretically. We measured the magnetic field distribution along the light propagation direction of the coils in experiment proving that the field has the relative fluctuation less than 1% in the range of 30cm along the direction.
Publisher
Trans Tech Publications, Ltd.
Reference10 articles.
1. D. Budker,M. Romalis, Optical magnetometry, Nature Physical, vol. 3(4), 2007, pp.227-234, doi: 10. 1038/nphys566.
2. J.S. Seltzer, Developments in Alkali-Metal atomic, New Jersey: Princeton university, (2008).
3. J.H. Zhang,Q. Liu X.J. Zeng J.X. Li,W.M. Sun, All Optical Cesium Atomic Magnetometer with high sensitivity, Chin. Phys. Lett., vol. 29, 2012, pp.0685011-0685013, doi: 10. 1088/0256-307X/29/6/068501.
4. J.M. Brown S.J. Smullin T.W. Kornack and M.V. Romalis, New Limiton Lorentz- and CPT-Violating Neutron Spin Interactions, Physical Review Letters, vol. 105(15), 2010, 151604. pp.1516041-1516044, doi: 10. 1103/PhysRevLett. 105. 151604.
5. T.W. Kornack, A Test of CPT and Lorentz Symmetry Using a K-3He Comagnetometer, New Jersey: Princeon University, (2005).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献