Affiliation:
1. Xi’an University of Technology
Abstract
This paper analyzed a kind of two-diode model and reasonably simplified the mathematical calculation process under different irradiance, proposing a method which can use maximum power point to calculate simultaneously series and parallel resistance. Two kinds of PV modules should be tested in order to validating the accuracy of the proposed method. It is calculated that the relative error of single diode model is 1.72% and the two-diode model is 0.45%. The result shows that more accuracy can be performed for two-diode model in reflecting the output characteristics of photovoltaic cells.
Publisher
Trans Tech Publications, Ltd.
Reference5 articles.
1. Qi Ren: Research and implementation of single phase photovoltaic grid-connected inverter systems[D]. QingDao University, June (2008).
2. K. Ishaque, Z. Salam: Simple, fast and accurate two-diode model for photovoltaic modules. Solar energy Materials and Solar Cells 95 (2)(2011), 586–594.
3. D. Sera, R. Teodorescu, P. Rodriguez: PV panel model based on datasheet values, in: Proceedings of the IEEE International Symposium on Industrial Electronics (ISIE), 2007, p.2392–2396.
4. De Soto W, Klein SA, Beckman WA: Improvement and validation of a model for photovoltaic array performance. Sol Energy 2006; 80: 78–88.
5. J.A. Gow, C.D. Manning: Development of a photovoltaic array model for use in power-electronics simulation studies. Power Apply, Vol. 146, No. 2, March (1999).
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献