Affiliation:
1. Tohoku University
2. Tohoku University Graduate School of Dentistry
Abstract
Surface titanium oxide (TiO2) films were fabricated on implant titanium (Ti) at low
temperatures by electron-cyclotron-resonance (ECR) plasma oxidation. The relationship among
the oxidization conditions, crystal structure, morphology and osteoconductive property were
investigated. Although crystallized TiO2 film was not prepared by thermal oxidation at 300°C,
crystallized rutile-type TiO2 film was formed by ECR plasma oxidation at 300°C. Rough
morphology was observed in the substrate surface oxidized by ECR plasma. Mixtures of
octacalcium phosphate (OCP) and dicalcium phosphate dihydrate (DCPD) were observed after
calcification. The XRD peak intensities of the OCP and DCPD formed on the ECR plasma
oxidized Ti were larger than those of calcified on the thermal oxidized Ti. ECR plasma
oxidation at low temperature would induce osteoconductive calcium phosphate on implant Ti.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献