Affiliation:
1. Nanyang Technological University
2. University of Warwick
Abstract
The quality of the interfaces in multilayer composites is a critical issue in the reliability
testing of the composite product during the manufacturing process and in-service. Weak interfaces
have often gone undetected and may become potentially defective at a later stage. One example is the
interface between mold compound and silicon (MC/Si) in IC packaging. There is a desire to study the
interface quality quantitatively, so the potential defective area can be evaluated and identified early. In
this paper, a nondestructive evaluation methodology is proposed to measure the available strength of
the interface by using ultrasonic reflection coefficients. It is known that interface degradation can be
either due to poor manufacturing process and stress loading. Characterization of the interface quality
of the MC/Si interface is first conducted by measuring longitudinal ultrasonic wave reflections from
the interface samples fabricated under varying conditioning processes that simulate the degradation.
A combined test that measures the reflection coefficient of the interface under stress load has also
been conducted to quantify the effect of the load. Finally, it is shown that the overall effect on the
reflection coefficient and available strength of the interface is derived and can be used as a
quantitative indicator.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Reference5 articles.
1. N. Guo, J. Abdul, H. Du, and B.S. Wong, J. Adhes. Sci. Technol., 16 (2002) 1261-1279.
2. J. Abdul, Y. Wang, N. Guo, A. -U. Rehman, and K.C. Chan, IEEE Trans. Electron. Packag. Manuf., 26 (2003) 221-227.
3. Otsuka, M., et al., (1998), IEEE Electronic Components and Technology Conference, 1167-1172.
4. Schmidt R., et al., (1998), IEEE/CPMT Electronics Packaging Conference.
5. H.C. Yeo, et al., (2006), Microelectronics Reliability, submitted.