Abstract
A new method for calibrating stereo vision measurement system is presented. By moving a rigid optical reference bar in a pattern in and around the measurement volume, the relative orientation and position of the two cameras can be determined by using the epipolar constraint, the linear normalization eight-point algorithm and the M-estimator method. The scale factor of the translation between the two cameras can be calculated by the distances between the marks on the reference bar. With automatically controlled infrared LED marks, the imaging feature points have a uniform intensity profile and a high contrast with background. The calibration accuracy can be improved. The simulation and experiments have shown that the calibration accuracy can be comparable with the complex off-line calibration.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Reference7 articles.
1. C.S. Fraser: Photogrammetric Record, Vol. 16 (1998), p.37.
2. W. Bösemann: Photogrammetric Record, Vol. 16 (1998), p.187.
3. G. Ganci and H.B. Handley: ISPRS Commission V Symposium, Japan, Vol. 32 (1998), p.53.
4. T. Liu, L.N. Cattafesta and R.H. Radeztsky: AIAA Journal, Vol. 38 (2000), p.964.
5. Z. Yu, G. Chen and R. Che: Second International Conference on Image and Graphics, Hefei, Vol. 4875 (2002), p.333.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献