Clinical Outcome of Current Generation Hydroxyapatite Coated Acetabular Design

Author:

Hermida Juan C.1,D'Lima Darryl D.1,Steklov Nikolai,Colwell Clifford W.1

Affiliation:

1. Scripps Health

Abstract

Hydroxyapatite (HA) coatings for femoral stems have been successful in short- to intermediate-term follow up. However, the outcomes of HA-coated cups have not been as successful as comparable non-HA-coated designs. This has been attributed to component design and to poor quality HA-coating processes. This is a clinical outcome study of a newer generation acetabular design with an improved plasma-sprayed HA-coat. Ninety consecutive primary total hip replacements implanted with a HA-coated metal-backed cup were prospectively followed up for 2–5 years after surgery. Mean age was 69 years, male:female ratio was 36:47; mean-weight was 77 kg. Polyethylene wear was measured on digitized images. Component position, component migration, and implant-bone interface radiolucent lines were analyzed by computerized image analysis. Hip-scores improved from preoperative mean 59(±12) to a final follow-up mean of 91(±12). One hip was revised for recurrent dislocation. No hips were revised for aseptic loosening. Mean acetabular abduction angle was 46°(±8.5) and anteversion was 18°(±8.7). Incomplete lucent lines were noted on early postoperative radiographs in 5% of the cases. With ongoing follow up radiolucent line thickness decreased by mean 13% and radiolucent line density increased by 11%. No cup had complete continuous radiolucent lines or lysis. Mean polyethylene linear and volumetric wear rates were 0.14(± 0.15) mm/year and 73(± 70) mm3/year respectively. Wear rates were higher in males (p<0.03). No other factor (age, body weight, cup abduction or anteversion angle) correlated significantly with wear rate. This study presents encouraging short-term results. The improvement in radiolucent lines suggests a beneficial effect of the HA-coat on bone ingrowth. None of the cups loosened or migrated. Wear rates were comparable to published reports of successful non-HA-coated cups. Long-term follow up is ongoing to corroborate these early findings.

Publisher

Trans Tech Publications, Ltd.

Subject

Mechanical Engineering,Mechanics of Materials,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3