Affiliation:
1. Tokyo University of Science
Abstract
The thickness dependency of the temperature image obtained by an infrared thermography was investigated using specimens with three kinds of materials and four kinds of the thickness of the specimen. Then, the infrared hybrid method was developed to separate individual stress components. However, it had the influence by heat conduction in the infrared stress measuring method. Therefore, an error will occur in the infrared hybrid analysis. Then, the system which corrected the error by the inverse analysis was developed. Thereby, the accuracy of the stress intensity factor was able to be raised. Furthermore, the accuracy of hybrid method considering to heat conduction was discussed in comparison with the 3-D finite-element analysis and 2-D hybrid method.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Reference7 articles.
1. K. Kishimoto, �H. Inoue, H. Shinbo and T. Shibuya: JSME Int. J., 40 (1997), p.108.
2. K. Hayabusa, K. �Kishimoto, H. Inoue�and T. Shibuya: JSME Int. J., 42 (1999), p.618.
3. T. Nishioka, K. Kurio and H. Nakabayashi: Exp. Mech., 40-2 (2000), p.170.
4. T. Nishioka, T. Fujimoto and R. Nishioka: Trans. JSME, 67-655A (2001), p.424.
5. K. Machida and M. Sato: Key Eng. Mat., 270-273 (2004), p.1262.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献