Abstract
Because titanium alloy Ti6Al4V features low density, good corrosion resistance and biocompatibility, it a metal of choice for medicine, used in orthopedics, accident surgery and dentistry. The insertion of elements such as nitrogen, carbon, hydrogen, iron or oxygen improve fatigue strength of this material. This paper presents certain basic fatigue and monotonic tests performed on the alloy. We have proposed a unique sample geometry and sample dimensions smaller than the reference ones. The dimensions of the working part of the sample correspond to the geometry of a dental implant connector. This part of the implant has to withstand stresses that are both intricate and variable in time. We performed monotonic tensile strength tests and uniaxial fatigue tests using the Instron 8874 machine. Then, we examined the samples under a stereoscopic microscope and measured the fracture development angle.
Publisher
Trans Tech Publications, Ltd.
Subject
Condensed Matter Physics,General Materials Science,Atomic and Molecular Physics, and Optics