In previous study, the quantitative measurement method of contact stiffness of the joint considering real contact area is developed by experimental approach. However, the measurement of contact stiffness needs special device and skillful measuring technique. Therefore, in this paper, simplified calculation method with material properties and profile data of surface roughness obtained by profilometer is considered. As a result, real contact area, contact stiffness and contact spring stiffness calculated from specific wavelength of rough surface are near agreement with experimental value. Hence, it is revealed that there is dominant configuration in surface roughness.
Publisher
Trans Tech Publications, Ltd.
Reference13 articles.
1. Y. Ito, Modular design for machine tools, The McGraw-Hill Companies Inc, New York, (2008).
2. Z.M. Levina, Research on the static stiffness of joint in machine tools, Proc. of the 8th Int. MTDR Conf. Part2 (1967) 737-758.
3. Y. Ito, S. Itoh, Contact Pattern Measurement by Means of Ultrasonic Waves: Art of Present and Some Improvements of its Performance, J. Vib. Acous. Trans. ASME. 105 (1983) 237-241.
4. S. Shimizu, K. Nakamura, H. Sakamoto, Quantitative Measurement Method of Contact Stiffness of the Joint with Different Material Combination. J. Adv. Mech. Des. Sys. Manuf. 4 5 (2010) 1144-1153.
5. S. Shimizu, K. Nakamura, H. Sakamoto, Relationship between longitudinal elastic modulus and contact stiffness of Differenet Material Combination, Proc. 4th CIRP HPC, C30 (2010) 195-200.