This paper reports on initial results from the first device tested of a “second generation”
Pt-SiC Schottky diode hydrogen gas sensor that: 1) resides on the top of atomically flat 4H-SiC
webbed cantilevers, 2) has integrated heater resistor, and 3) is bonded and packaged. With proper
selection of heater resistor and sensor diode biases, rapid detection of H2 down to concentrations of 20
ppm was achieved. A stable sensor current gain of 125 ± 11 standard deviation was demonstrated
during 250 hours of cyclic test exposures to 0.5% H2 and N2/air.