Affiliation:
1. Northeastern University
Abstract
A physical thermal model was established in this study, and the gas temperature in the model was measured with temperature sensors under different experimental conditions. The results show that the packed bed, cohesive zone, dripping zone and raceway in melter gasifier can be roughly distinguished by temperature gradient analysis along the vertical direction. The changes of different zones in the COREX melter gasifier were also investigated in this paper under different operation conditions.
Publisher
Trans Tech Publications, Ltd.
Reference12 articles.
1. H.F. Li, C. Wang, Z.S. Zou, et al: Baosteel Technology, (2008), p.19. (In Chinese).
2. Pal S, Lahiri A K: Metallurgical and Materials Transactions B, Vol. 34B (2003), p.103.
3. Lee S C, Shin M K, Joo S, et al: ISIJ International, Vol. 39 (1999), p.319.
4. Lee S C, Shin M K, Joo S, et al: ISIJ International, Vol. 40 (2000), p.1073.
5. W.G. Zhong, F. Zh. Ji: Science & Technology of Baotou Steel(Group) Corporation, (1983), p.44. (In Chinese).
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献