Affiliation:
1. Academy of Armored Force Engineering
2. Military Medical Science Academy
Abstract
Based on the uniformity of magnetic field in shear circle, low magnetic field, and inconvenient of injecting magnetorheological fluid (MRF), the rotational parallel disk instrument for measuring the shear stress of MRF made by ourselves was improved. The magnetic circuit of the instrument was optimized using Ansys software, the parts and structure of leaking magnetic field were improved, and the uniformity of the magnetic field in shear circle plates was strengthen; when the current was 1.65A, the average magnetic field in shear circle plates was 0.9T. Then the influence on MRF by using different mass fractions of nano-Fe3O4 was researched, which indicate when the ration between the mass of nano-Fe3O4 and that of carbonyl iron particles is 5%, the characteristic of MRF is best.
Publisher
Trans Tech Publications, Ltd.
Reference7 articles.
1. Rabinow J. The magnetic fluid clutch[J]. AIEE Transaction, 1948, 67: 1308-1315.
2. Carlson J D, Chrzan M J, Raleigh N C and Girard F J 1994 US Patent: 5284330.
3. Viota J L, Vicente J D, Duran J D G and Delgado A V 2005 J. Colloid Interface Sci. 284, 527.
4. Jolly M R, Bender J W, Carlson J D. Properties and applications of commercial magnetorheological fluids[J]. Journal of Intelligent Material Systems and Structures, 1999, 10: 5-13.
5. Ismo V 2002 Smart Mater. Struct. VTT Research Program 2000-2002, 51.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献