Affiliation:
1. Hebei University of Technology
Abstract
A high frequency coaxial transformer (HFCT) with a split winding structure and litz wire has been developed for high frequency (HF) and high power DC/DC converter applications. A method combined numerical analysis of magnetic field and analytical calculation of litz wire winding losses, taking into account conduction losses and proximity effect losses, is proposed for the designed HFCT. The experimental results validate the winding loss calculation method. The measured results demonstrate that the voltage ratio has a good agreement with the turn ratio over the frequency range from 0.1MHz to 1MHz, indicating that the high coupling efficiency has been obtained.
Publisher
Trans Tech Publications, Ltd.
Reference10 articles.
1. J. Lu and F. Dawson, Analysis of Eddy Current Distribution in High Frequency Coaxial Transformer with Faraday Shield, IEEE Trans. on Magnetics, 42(10): 3171-3173, (2006).
2. J. Lu, F. P. Dawson and S. Yamada, Application and analysis of adjustable profile high frequency switch mode transformer having a U-shaped winding structure, IEEE Trans. on Magnetics, 34(4): 1345-1347, (1998).
3. K.W. Klontz, and et. . al, An active cooled 120kW coaxial winding transformer for fast charging electric vehicles, IEEE Trans. on Industry Applications, 31(6): 1257-1263, (1995).
4. J. Kuang, X. Ruan, and X. Ren. Analysis of Skin and Proximity Effects onWinding Losses in PlanarMagnetic Components, Proceedings of the CSEE, 26(5): 170-175, (2006).
5. Hurley W G,Gath E,Breslin J G.Optimizing the AC resistance of multilayer transformer windings with arbitrary current waveforms, IEEE Transactions on Power Electronics, 15(2): 369-376, (2000).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献