Affiliation:
1. Malek-Ashtar University of Technology
Abstract
ZrO2-8wt.%Y2O3 (8YSZ) thermal barrier coatings (TBCs) were deposited by atmospheric plasma spraying (APS) on NiCoCrAlY-coated Inconel 738LC substrates. The thermal shock behavior was investigated by quenching the samples in water with temperature of 20-25°C from 950°C. To study of failure mechanism results from thermal cycling, microstructural evaluation using scanning electron microscope (SEM), elemental analysis using energy dispersive spectroscopy (EDS) and phasic analysis using x-ray diffractometry (XRD) were done. The results revealed that failure of the TBC system was due to the spallation of ceramic top coat. Thermal mismatch stress was the major factor of TBC failure in thermal shock test.
Publisher
Trans Tech Publications, Ltd.
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献