Abstract
International thermonuclear experimental reactor (ITER) soft x-ray (SXR) diagnostic camera is an indispensible component used to measure signal intensity of SXR, which can reflect the internal properties of plasma. In this paper, the preliminary structural design and working principle of SXR camera is demonstrated, to investigate its seismic performance, modal analysis has been performed to obtain natural frequencies, effective mass and mode of vibration in first ten modes by means of ANSYS software. Then according to two parallel seismic analysis methods used in ITER, the calculations have been performed and the corresponding results have been illustrated respectively, the stress intensity and displacement are all within the allowable margin, which indicates that the design is reasonable and feasible. It will also provide beneficial reference for subsequent work.
Publisher
Trans Tech Publications, Ltd.
Reference10 articles.
1. Yu Dong-man, Yao Da-mao, Xie Han, etc. Seismic response analysis for equatorial diagnostic port plug of international thermonuclear experimental reactor. J. Cent. South Univ. Technol. (2009) 16: 0112-0118.
2. ASCE Standard 4-98 Seismic Analysis of Safety-Related Nuclear Structures and Commentary,. ISBN 0-7844-0433-X.
3. C. Bachmann. 2010, Load Specification for the ITER Vacuum Vessel. France: ITER_D_2F52JY.
4. G. Sannazzaro, G. Mazzone. 2010, Template for analysis document on calculation of ITER Tokamak Complex seismic loads from heavy equipment. France: ITER_D_3V74UZ.
5. J-M. Martinez. 2010, Analysis of the Structural Margin of the Reinforced VV Lower Port Poloidal Gussets. France: ITER_D_2LNFJN.