Affiliation:
1. Beijing University of Technology
2. Tangshan College
3. Hebei United University
Abstract
A new cooling concept for high power LED street lamp by combining the heat release of high power LED with two-phase heat transfer heat pipes was proposed, and in this paper we study the effect of heat pipe numbers, fins structure and ambient temperature on the performance of heat dissipation of HP heat exchanger. Through experimental results, we found the heat pipes number plays a more importent role on the performance of heat dissipation than the fins material and the final surface temperature will increase with the environmental temperature.
Publisher
Trans Tech Publications, Ltd.
Reference6 articles.
1. James Petroski. Spacing of High-Brightness LEDs on Metal Substrate PCB's for Proper Thermal Performance. IEEE Inter Society Conference on Thermal Phenomena (2004), 507-514.
2. Daniel J, Schlitz. Electro-hydrodynamic gas flow led cooling system, [P]Publication No. US 2010/0177519.
3. Chen Wei, Luo Xiao-Bing. Experimental Investigation on Micro Jet Cooling System for High Power LED, Semconductor optoelectronics, Vol. 28, No 4: 478-481.
4. Liu S, Lin T, Luo X B, et al. A microjet, array cooling system for thermal management of active radars and high-brightness LEDs [A]. Fifty-Sixth Electronic Components & Technology Conference[C]. 2006. 1634-1638.
5. Mo Dong-Chuan. Start-up Characteristic of Flatten Loop Heat Pipe Using in LED. Journal of Engineering Thermophysics. Vol. 30 No. 10:. 1759-1762.